QA@IT

ダイヤルアップ接続の方法

3290 PV

私は現在Cisco891Fを使用して、INS網を経由し、対向先のダイヤルアップルータと接続しようと試みています。
BRIインターフェースやDialerインターフェースのStatusとProtocolはupになっているのですが、対向先ルータへpingが届きません。
"debug dialer"コマンドを実行してから対向先へpingを実行した際の結果は以下の通りです。


Router#ping XXX.XXX.XXX.XXX
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to XXX.XXX.XXX.XXX, timeout is 2 seconds:

*Jan 21 07:01:57.610: BR0 DDR: rotor dialout [best] least recent failure is also most recent failure
*Jan 21 07:01:57.610: BR0 DDR: rotor dialout [best] trying untried dialout
*Jan 21 07:01:57.610: BR0 DDR: rotor dialout [best] also has most recent failure
*Jan 21 07:01:57.610: BR0 DDR: rotor dialout [best]
*Jan 21 07:01:57.610: BR0 DDR: Dialing cause ip (s=YYY.YYY.YYY.YYY, d=XXX.XXX.XXX.XXX)
*Jan 21 07:01:57.610: BR0 DDR: Attempting to dial 057AAAAAAA.
*Jan 21 07:02:00.050: %DIALER-6-BIND: Interface BR0:1 bound to profile Di1
*Jan 21 07:02:00.050: BRI0:1: Perform line action on hwidb for PPP and HDLC
*Jan 21 07:02:00.614: BR0:1 DDR: disconnecting call
*Jan 21 07:02:00.838: BR0 DDR: has total 0 call(s), dial_out 0, dial_in 0.
*Jan 21 07:02:00.838: %DIALER-6-UNBIND: Interface BR0:1 unbound from profile Di1
*Jan 21 07:02:01.610: BR0 DDR: rotor dialout [best] least recent failure is also most recent failure
*Jan 21 07:02:01.610: BR0 DDR: rotor dialout [best] trying untried dialout
*Jan 21 07:02:01.610: BR0 DDR: rotor dialout [best] also has most recent failure
*Jan 21 07:02:01.610: BR0 DDR: rotor dialout [best]
*Jan 21 07:02:01.610: BR0 DDR: Dialing cause ip (s=YYY.YYY.YYY.YYY, d=XXX.XXX.XXX.XXX)
*Jan 21 07:02:01.610: BR0 DDR: Attempting to dial 057AAAAAAA.
*Jan 21 07:02:04.138: %DIALER-6-BIND: Interface BR0:1 bound to profile Di1
*Jan 21 07:02:04.138: BRI0:1: Perform line action on hwidb for PPP and HDLC
*Jan 21 07:02:04.686: BR0:1 DDR: disconnecting call
*Jan 21 07:02:04.826: BR0 DDR: has total 0 call(s), dial_out 0, dial_in 0.
*Jan 21 07:02:04.826: %DIALER-6-UNBIND: Interface BR0:1 unbound from profile Di1
*Jan 21 07:02:05.610: BR0 DDR: rotor dialout [best] least recent failure is also most recent failure
*Jan 21 07:02:05.610: BR0 DDR: rotor dialout [best] trying untried dialout
*Jan 21 07:02:05.610: BR0 DDR: rotor dialout [best] also has most recent failure
*Jan 21 07:02:05.610: BR0 DDR: rotor dialout [best]
*Jan 21 07:02:05.610: BR0 DDR: Dialing cause ip (s=YYY.YYY.YYY.YYY, d=XXX.XXX.XXX.XXX)
*Jan 21 07:02:05.610: BR0 DDR: Attempting to dial 057AAAAAAA.
Success rate is 0 percent (0/5)
Router#
*Jan 21 07:02:08.226: %DIALER-6-BIND: Interface BR0:1 bound to profile Di1
Router#
*Jan 21 07:02:08.226: BRI0:1: Perform line action on hwidb for PPP and HDLC
*Jan 21 07:02:08.778: BR0:1 DDR: disconnecting call
Router#
*Jan 21 07:02:11.366: BR0 DDR: has total 0 call(s), dial_out 0, dial_in 0
Router#
*Jan 21 07:02:11.366: %DIALER-6-UNBIND: Interface BR0:1 unbound from profile Di1
Router#

ちなみに、"show dialer interface Dialer 1"を実行して結果を確認したところ、"Successes"のカウンター値のみが増加しているのでISDN番号が間違っていることはないと思います。

どなたか、状況改善のためにアドバイスを頂けますと幸いです。

回答

ルーティングはどうなっておりますでしょうか。

編集 履歴 (0)
ウォッチ

この質問への回答やコメントをメールでお知らせします。